System Specifications
Applications
Abdominal
Small parts and superficial
Pediatric
Musculoskeletal
Obstetrical
Gynecological and fertility
Prostate
Vascular
– Cerebrovascular
– Peripheral vascular
– Intraoperative vascular
Transcranial Doppler
Cardiac
– Adult
– Pediatric
– Transesophageal
– Stress
Contrast imaging
ICE Imaging (Intracardiac Echocardiography)

2D grayscale imaging with advanced Fusion frequency
compounding technology
Tissue Harmonic Imaging with Pulse Inversion technology
SonoCT beam-steered real-time compound imaging
Harmonic SonoCT imaging
XRES adaptive image processing technology
iSCAN intelligent scanning for one-button TGC, gain and
compression map optimization
Simultaneous 2D and M-mode
Color M-mode
Anatomical M-mode
– Trace can be generated or modified post-Freeze, from 2D image data in Quick Review buffer
Adaptive Color Doppler for automatic selection of optimal color frequency
Color Tissue Doppler Imaging
Pulsed wave Tissue Doppler Imaging
Color Power Angio Imaging (CPA) and directional CPA
Intelligent Doppler for maintaining specified scanning angles during flow adjustments
Adaptive Doppler for boosting weak signals and reducing noise
Duplex 2D/PW Doppler
High-PRF pulsed wave (PW) Doppler
Color compare
– Real-time color/2D images
Triplex 2D, CPA, PW Doppler
Dual imaging with:
– Independent cineloop buffers
– Mixed mode display with one image live while other is frozen, for example 2D/2D, 2D/color, color/color, color/CPA
High Definition zoom (write zoom)
Reconstructed zoom with pan (read zoom)
Panoramic imaging
Trapezoidal imaging
Freehand 3D and MPR imaging
Automated 3D and real-time 4D imaging with harmonics and color modes
Automated 3D fetal echo STIC (Spatio-Temporal Image
Correlation)
Chroma imaging in 2D, 3D, 4D, MPR, panoramic, M-mode, Doppler modes and CW/PW
Contrast imaging
Gray Shades
256 (8 bits) in 2D, M-mode and Doppler spectral analysis
Acquisition Frame Rate
2D frame rate acquisition greater than 785 frames per second (dependent on transducer, field of view, depth and angle)
Color frame rate acquisition greater than 320 Hz (dependent on transducer, field of view, depth and angle)
The automated volume transducers are lightweight and small with an ergonomic design for improved user comfort during exams. The C6-3 smaller curved array transducer improves intercostal access. The new BP10-5ec transducer supports biplane prostate imaging

 

Kapcsolódó eszközök

Philips L12-3

Philips S4-2

Philips S4-2